CLASS II

Combustible Dusts


Class II Area Classifications

Division 1:
Where ignitable concentrations of cumbustible dusts can exist all of the time or some of the time under normal operating conditions.

Division 2:
Where ignitable concentrations of cumbustible dusts are not likely to exist under normal operating conditions.

Class II Groups

Division 1 & 2
E (metals)
F (coal)
G (grain)

Class II Temperature Codes

Division 1 & 2
T1 (450ºC)

T2 (300ºC)
T2A, T2B, T2C, T2D
(280ºC, 260ºC, 230ºC, 215ºC)
T3 (<200ºC)
T3A, T3B, T3C
(180ºC, 165ºC, 160ºC)
T4 (135ºC)
T4A (120ºC)
T5 (100ºC)
T6 (85ºC)
Class II, Division 1 and 2 Protection Methods
Area Protection Methods Applicable Certification Standards
U.S. Canada
Div. 1 • Dust-ignition
• Intrinsically safe
• Pressurized
ANSI/UL 1203
ANSI/UL 913
ANSI/NFPA 496
CSA-25 or CSA-E1241-1-1
CSA-157
ANSI/NFPA 496
Div. 2 • Dusttight
• Nonindendive
• Non-sparking
• Pressurized
• Any Class II, Div. 1 method
UL 1604
UL 1604
UL 1604
ANSI/NFPA 496
----
CSA-157 or CSA-E1241-1-1
----
----
ANSI/NFPA 496
----
Hazardous Location Markings
Class I, II & III, Division 1 & 2 (U.S. & Canada) - This marking would include: Class(es), Division(s), Gas/Dust Group(s), Temperature Code Example: Class I, Division 1, Group C & D, T4A
Class I, Zone 0, 1 and 2 (U.S. & Canada) - This marking would include: Method A: For Zone Listings based on UL 2279 or the CSA-E79 Series Class, Zone(s), Ex, Protection Method(s), Gas Group, Temperature Code Example: Class I, Zone 1, Ex de IIB T4 Method B: For Zone Listings based on UL or CSA Division Standards Class, Zone(s), Gas Group, Temperature Code Example: Class I, Zone 1, Group IIB, T4
Note: For Canadian Zone Listings based on the CSA-E79 Series, the "Class" and "Zone" elements of the markings string are optional
Zone 0, 1 and 2 (IEC only) - This marking would include: Ex, Protection Method(s), Gas Group, Temperature Code Example: Ex de IIB T4
Zone 0, 1 and 2 (Europe only) - This marking would include: EEx, Protection Method(s), Gas Group, Temperature Code Example: EEx de IIB T4

Epsilon Ex The "Epsilon Ex" is the European mark indicating compliance with CENELEC requirements. This mark is recognized by all European Union member countries as a legal means of entry under the European Directives for Potentially Explosive Atmospheres, 761/117/EEC and 79/117/EEC. UL's Hazardous Locations staff can assist in obtaining both this mark and the associated Certificates of Conformity from a variety of European-Approved (Notified) Bodies. In addition to Notified Bodies such as KEMA and PTB, UL can also work directly through DEMKO A/S, a wholly owned subsidiary of Underwriters Laboratories Inc., to obtain the "Epsilon Ex" mark and the associated Certificates of Conformity. This relationship with DEMKO A/S, in conjunction with UL's other domestic and international services, now makes the process of gaining access to your key markets easier than ever.
Underwriters Laboratories Inc. . 333 Pfingsten Road . Northbrook, IL 60062 . 847-272-8800 (voice) . 847-272-8129 (fax)
 

[ Home | Company Information | Products | Technical Information | Contact LDPI® ]
[ Request Catalog | Place Order | Lighting Calculations | Related Links ]

LDPI® is a Registered Trademark of LDPI, Inc.
Names of companies and/or products mentioned in this site
are trademarks of their respective owners.

Copyright© 2008 by LDPI, Inc. All rights reserved.
Please direct site problems or questions to administrator@ldpi-inc.com